Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
1764201
Reference Type
Journal Article
Title
RAPID AND SENSITIVE SIMULTANEOUS ESTIMATION OF METFORMIN HYDROCHLORIDE AND PIOGLITAZONE HYDROCHLORIDE IN TABLET FORMULATION BY HPTLC METHOD
Author(s)
Modi, DK; Patel, BH
Year
2013
Is Peer Reviewed?
Yes
Journal
Journal of Liquid Chromatography and Related Technologies
ISSN:
1082-6076
EISSN:
1520-572X
Volume
36
Issue
5
Page Numbers
618-627
Language
English
DOI
10.1080/10826076.2012.673202
Web of Science Id
WOS:000315349900007
URL
https://www.proquest.com/scholarly-journals/rapid-sensitive-simultaneous-estimation-metformin/docview/1313233516/se-2?accountid=171501
Exit
Abstract
A rapid, simple, and sensitive HPTLC method for simultaneous estimation of two antidiabetic drugs, metformin hydrochloride and pioglitazone hydrochloride, in pharmaceutical tablet was developed and validated. Separation was achieved on aluminum sheets of silica gel 60F254 using butanol:1, 4-dioxane:glacial acetic acid (5:3:2, v/v/v) as the mobile phase. This system gave a good resolution for metformin hydrochloride (R f value of 0.36 +/- 0.01) and pioglitazone hydrochloride (R f value of 0.73 +/- 0.01). Detection and quantification was carried out at 226nm. Calibration plot was constructed in the range of 2000 to 20000ng/band for metformin hydrochloride and 60 to 600ng/band for pioglitazone hydrochloride. The linear regression data for the calibration plot showed a good relationship with r=0.9960 and 0.9968 for metformin hydrochloride and pioglitazone hydrochloride, respectively. Assays for metformin hydrochloride and pioglitazone hydrochloride were 99.6% (RSD 0.618%) and 99.7% (RSD 0.511%), respectively, for the brand analyzed. The method was validated for precision and recovery. The limits of detection and quantification were 629.89 and 1908.76ng/band for metformin hydrochloride and 8.51 and 25.77ng/band for pioglitazone hydrochloride, respectively.
Keywords
HPTLC; metformin; oral antidiabetics; pharmaceutical analysis; pioglitazone
Tags
OPPT REs
•
OPPT_1,4-Dioxane_D. Exposure
Total – title/abstract screening
Supplemental Search
Consumer Use
•
OPPT_1,4-Dioxane_F. Human Health
Total – title/abstract screening
Off topic
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity