Health & Environmental Research Online (HERO)


Print Feedback Export to File
2669076 
Journal Article 
Study of DBD Precipitator Energized by a Modified Square Waveform Voltage 
Gouri, R; Tilmatine, A; Zouzou, N; Dascalescu, L 
2013 
IEEE Transactions on Dielectrics and Electrical Insulation
ISSN: 1070-9878
EISSN: 1558-4135 
20 
1540-1546 
This experimental work is aimed at evaluating the effects of high voltage waveform (modified square waveform) on the collection efficiency of a wire-to-square tube electrostatic precipitator using dielectric barrier discharge. The experiments are performed with incense smoke particles having a mean size of about 0.32 mu m. An aerosol spectrometer is employed for characterizing the size distribution of these particles at the outlet of the electrostatic precipitator. The collection efficiency is estimated for various applied voltages (ranges: 4 to 20 kV) at fixed frequency (100 Hz) and flow rate (10 L.min(-1)). The input parameters under study are the pulse duration, the rise and fall times, the presence of an Offset, and the plateau of the high voltage. The experimental results show that the square waveform with modified plateau is able to increase the performance of the electrostatic precipitation. 
Dielectric barrier discharge; high voltage waveform; electrostatic precipitation