Health & Environmental Research Online (HERO)


Print Feedback Export to File
4090388 
Technical Report 
Flexible Neutron Shielding for a Glovebox Within the Idaho National Laboratory Radioisotope Power System Program. AGS Annual Conference and Expo 2007 
Walsh, S 
2007 
NTIS/03180131 
GRA and I 
GRA and I 
Neutron shielding was desired to reduce worker exposure during handling of plutonium-238 (Pu-238) in a glovebox at the Idaho National Laboratory. Due to the unusual shape of the glovebox, standard methods of neutron shielding were impractical and would have interfered with glovebox operations. A silicon-based, boron-impregnated material was chosen due to its flexibility. This paper discusses the material, the installation, and the results from neutron source testing. Neutron shielding was desired to reduce worker exposure during handling of plutonium-238 (Pu-238) in a glovebox at the Idaho National Laboratory. Due to the unusual shape of the glovebox, standard methods of neutron shielding were impractical and would have interfered with glovebox operations. A silicon-based, boron-impregnated material was chosen due to its flexibility. This paper discusses the material, the installation, and the results from neutron source testing.