Health & Environmental Research Online (HERO)


Print Feedback Export to File
4746570 
Journal Article 
Simultaneous detection of Mn, Co, Ni, and Cu using ion chromatography coupled with ICP-MS with a special focus on the determination of Ni-59 in corrosion deposits 
Plausinaitis, D; Knasiene, B; Prokopchik, A; Naujalis, E; Claramunt, AV 
2018 
Yes 
Journal of Radioanalytical and Nuclear Chemistry
ISSN: 0236-5731
EISSN: 1588-2780 
316 
257-265 
A simple method for the simultaneous detection of stable and long-lived Mn, Ni, Co and Cu isotopes has been created by coupling an ion chromatographic system (IC) to an ICP-MS. The analytical procedure was tested with two chromatographic columns: a strong cation exchange and an anionic/cationic mixed bed. It was found that the best separation of the metals is typically obtained when mobile phase contains 0.05 mol/L of tartaric acid. Ammonia solution was used for adjustment of the eluent's pH and this avoided contamination of the ICP-MS with eluent metals. The developed method was demonstrated in researching the samples of corrosion deposits from a pipeline of a nuclear power plant. The established Ni-59 scaling factor to Co-60 being 3.8 x 10(-2) and it's correlated to the literary data. 
Ni-59; Ni-63; ICP-MS; Ion chromatography; On-line measurement; Radioactive waste