Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
5154334
Reference Type
Journal Article
Title
Rapid Determination of Anthracene and Benzo(a) pyrene by High-Performance Liquid Chromatography with Fluorescence Detection
Author(s)
Rubio-Clemente, A; Chica, E; Penuela, GA
Year
2017
Is Peer Reviewed?
Yes
Journal
Analytical Letters
ISSN:
0003-2719
EISSN:
1532-236X
Publisher
Taylor and Francis Inc.
Volume
50
Issue
8
Page Numbers
1229-1247
Language
English
DOI
10.1080/00032719.2016.1225304
Web of Science Id
WOS:000405402200001
Abstract
A rapid and simple method was optimized and validated for the separation and quantification of anthracene and benzo(a)pyrene, two of the most toxic polycyclic aromatic hydrocarbons, at ultratrace levels in aqueous samples by direct injection. The determination of anthracene and benzo(a)pyrene was performed by reverse-phase high-performance liquid chromatography (HPLC) with fluorescence detection. A fractional factorial matrix and a BoxâBehnken design were chosen for screening and optimization purposes, respectively. The optimized parameters that significantly influenced the system were the flow rate (1 mL minâ1), mobile-phase strength (90% acetonitrile:10% deionized water), column temperature (35°C), and excitation wavelength (254 and 267 nm for anthracene and benzo(a)pyrene, respectively). The injection volume and emission wavelength were fixed at 100 µL and 416 nm, respectively. The quantification limits were 75 ng Lâ1 for anthracene and 30 ng Lâ1 for benzo(a)pyrene. The relative standard deviations for the recovery and intra and interday precision values were lower than 20%. The method allows the analysis of aqueous samples with a good resolution for anthracene and benzo(a)pyrene below values permitted by the recently developed European Directive 2013/39/EU for inland surface waters. In addition, this work provides guidelines for the simultaneous optimization of several parameters by experimental design. © 2017 Taylor & Francis.
Keywords
Box-Behnken design; direct injection; fluorescence; fractional factorial design; high-performance liquid chromatography; polycyclic aromatic hydrocarbons