5408799
Reference Type
Journal Article
Title
A reference measurement procedure for amino acids in blood using isotope dilution ultra-performance liquid chromatography-tandem mass spectrometry
Author(s)
Kim, J; Tran, TTH; Hong, SP; Jeong, JS
Year
2017
Is Peer Reviewed?
Yes
Journal
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
ISSN:
1570-0232
EISSN:
1873-376X
Volume
1055-1056
Page Numbers
72-80
Language
English
PMID
28445849
DOI
10.1016/j.jchromb.2017.04.027
Web of Science Id
WOS:000402357800010
Abstract
We described a reference measurement procedure for amino acid (AA) quantification in blood samples based on deproteinization with 5-sulfosalicylic acid (SSA) and an isotope dilution-ultra performance liquid chromatography-tandem mass spectrometry (LC-MS) method. The serum was deproteinized with 15% v/v SSA and the supernatant was injected directly into the LC-MS system without further processing. Compared with the use of other precipitants and water as a control, five model AAs-valine, isoleucine, leucine, tyrosine, and phenylalanine-in the SSA-treated samples showed ionization enhancement as well as stable background signals without significant ion suppression effects. Five analytes were clearly separated within 3min using gradient elution and ion-pair chromatography of water and acetonitrile containing 0.1% v/v trifluoroacetic acid. The limit of detection range of this method was 2-52fmol, and the RSDs of accuracy and precision from intra- and inter-day assays were within 2.7%. The method was applied to various blood samples including serum, whole blood and plasma, with no reasonable measurement bias revealed. The quantification accuracy of this method was then assessed using commercially available plasma certified reference material (CRM) for AA, and the results agreed well within certified values. We finally applied this method to the determination of candidate serum CRM. The optimized protocol was found to be suitable for the accurate quantification of five AAs in serum, and may satisfactorily serve as a primary method for AA measurement in various blood matrices.
Tags
PFAS
•
PFAS 150
Literature Search Update December 2020
PubMed
WOS
Literature Search August 2019
PubMed
Web of Science
Not prioritized for screening
Trifluoroacetic acid
•
PFAS Universe
Data Source
Web of Science
Pubmed
2,2,2-trifluoro-Acetic acid-d
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity