Title
Mixing and matching in ceramic-on-metal hip arthroplasty: An in-vitro hip simulator study
Author(s)
Affatato, S; Spinelli, M; Squarzoni, S; Traina, F; Toni, A
Year
2009
Is Peer Reviewed?
Yes
Journal
Journal of Biomechanics
ISSN:
0021-9290
EISSN:
1873-2380
Volume
42
Issue
15
Page Numbers
2439-2446
DOI
10.1016/j.jbiomech.2009.07.031
Abstract
The clinical success of second-generation metal-on-metal hip replacement and the good tribological performance of alumina ceramic revived an interest in hip articulation as a solution to reduce wear. This study was aimed at characterizing the wear behaviour of new hybrid ceramic-on-metal bearings. In particular, this study investigated the wear behaviour of ceramic-on-metal hip components (three different diameters configurations: 28, 32 and 36Â mm), not specifically proposed to be coupled, in order to compare them with ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. For this purpose, the weight loss over a standard wear simulation was monitored. Moreover, scanning electronic microscope observations were used to verify if any carbides removal, for the metallic components, triggered wears debris production promoting abrasive third-body wear. After five million cycles, our results showed significantly greater wear-in ceramic-on-metal compared with ceramic-on-ceramic, and significant greater wear for the 32-mm diameter compared with the 36-mm one. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones confirming that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behaviour, not even comparable with that of the ceramic-on-ceramic gold standard. Wear patterns and roundness tolerances certainly discourage the coupling of components not specifically intended to be coupled. Unsuitable geometrical conformity could, in fact, result in a poor dynamic behaviour and lead to clinical failure.
Keywords
Ceramic-on-metal; Roundness measurements; Hip wear rate; COC; COM; SEM