Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
6779431
Reference Type
Journal Article
Title
Levels of office blood pressure and their operating characteristics for detecting masked hypertension based on ambulatory blood pressure monitoring
Author(s)
Viera, AJ; Lin, FC; Tuttle, LA; Shimbo, D; Diaz, KM; Olsson, E; Stankevitz, K; Hinderliter, AL
Year
2015
Is Peer Reviewed?
Yes
Journal
American Journal of Hypertension
ISSN:
0895-7061
Volume
28
Issue
1
Page Numbers
42-49
Language
English
PMID
24898379
DOI
10.1093/ajh/hpu099
Web of Science Id
WOS:000347415100007
Abstract
BACKGROUND:
Masked hypertension (MH)--nonelevated office blood pressure (BP) with elevated out-of-office BP average--conveys cardiovascular risk similar to or approaching sustained hypertension, making its detection of potential clinical importance. However, it may not be feasible or cost-effective to perform ambulatory BP monitoring (ABPM) on all patients with a nonelevated office BP. There likely exists a level of office BP below which ABPM is not warranted because the probability of MH is low.
METHODS:
We analyzed data from 294 adults aged ≥ 30 years not on BP-lowering medication with office BP <140/90 mm Hg, all of whom underwent 24-hour ABPM. We calculated sensitivity, false-positive rate, and likelihood ratios (LRs) for the range of office BP cutoffs from 110 to 138 mm Hg systolic and from 68 to 88 mm Hg diastolic for detecting MH.
RESULTS:
The systolic BP cutoff with the highest +LR for detecting MH (1.8) was 120 mm Hg, and the diastolic cutoff with the highest +LR (2.4) was 82 mm Hg. However, the systolic level of 120 mm Hg had a false-positive rate of 42%, and the diastolic level of 82 mm Hg had a sensitivity of only 39%.
CONCLUSIONS:
The cutoff of office BP with the best overall operating characteristics for diagnosing MH is approximately 120/82 mm Hg. However, this cutoff may have an unacceptably high false-positive rate. Clinical risk tools to identify patients with nonelevated office BP for whom ABPM should be considered will likely need to include factors in addition to office BP.
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity