Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
7002780
Reference Type
Journal Article
Title
Minimising the risk of Mycobacterium chimaera infection during cardiopulmonary bypass by the removal of heater-cooler units from the operating room
Author(s)
Barker, TA; Dandekar, U; Fraser, N; Dawkin, L; Sweeney, P; Heron, F; Simmons, J; Parmar, J; ,
Year
2018
Is Peer Reviewed?
1
Journal
Perfusion
ISSN:
0267-6591
EISSN:
1477-111X
Publisher
SAGE PUBLICATIONS LTD
Location
LONDON
Page Numbers
264-269
PMID
29108485
DOI
10.1177/0267659117739103
Web of Science Id
WOS:000432108900004
Abstract
Introduction: Mycobacterium chimaera (M. chimaera) is a recently characterised bacterium that can cause life-threatening infections in small numbers of patients who undergo cardiopulmonary bypass during cardiac surgery. The likely mode of transmission is thought to occur through aerosolisation from contaminated water reservoirs. The airborne bacteria then contaminate the surgical field, leading to an infection months or even years later. The preferred practical solution to disrupt the transmission of these airborne bacteria to the patient is to remove the heater-cooler units (HCUs) from the operating room (OR). We describe a process of achieving this in order to provide information to guide other institutions who wish to do a similar thing.Methods: A multidisciplinary team was assembled to work on the project. The planning phase involved trialling different OR layouts and simulating the alterations in the HCU circuit function. The changes to the OR were made over a weekend to minimise disruption to the operating schedule.Results: The HCU was moved to the dirty utility room adjacent to the OR. Standard operating procedures (SOP) and risk assessments were made to enable this to be used for a dual purpose. One of the ORs was reconfigured to allow the cardiopulmonary bypass machine to be located close to the HCU in the dirty utility room. The total cost of the alterations was 6,158 pound. Although we have provided a physical barrier to interrupt patient exposure to aerosolised M. chimaera from HCUs, we continue to perform cultures and decontamination as per the national recommendations. The SOP was designed to be auditable to ensure compliance with the protocols.Conclusions: We show a method by which the HCU can be removed from the OR in a relatively low-cost, straightforward and practical manner.
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity