Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
7029270
Reference Type
Journal Article
Title
Long-term performance of a pacing lead family: A single-center experience
Author(s)
El-Chami, MF; Hoskins, MH; Delurgio, D; Lloyd, M; Langberg, J; Leon, AR; Merchant, FM; Rao, B; Shah, AD; Wood, C; Sayegh, M; Zakka, P; Ginn, K; Pallotta, L; Evans, B; ,
Year
2019
Is Peer Reviewed?
Yes
Journal
Heart Rhythm
ISSN:
1547-5271
EISSN:
1556-3871
Publisher
ELSEVIER SCIENCE INC
Location
NEW YORK
Page Numbers
572-578
PMID
30366161
DOI
10.1016/j.hrthm.2018.10.024
Web of Science Id
WOS:000462618400015
Abstract
BACKGROUND The performance of Abbott/St. Jude Medical (Sylmar CA) Tendril pacing leads has not been well characterized.OBJECTIVE We sought to assess the performance of Tendril leads as compared with that of different pacing leads.METHODS We retrospectively identified patients implanted with the following leads: Tendril leads 1888 TC, 2088 TC, and 1688 TC, Medtronic (Fridely, MN) 4076 CapSureFix Novus, and Boston Scientific (Natick, MA) FINELINE II Sterox Pacing EZ leads (models 4469, 4470, and 4471). The primary end point was the incidence of lead malfunction assessed by Kaplan-Meier analysis.RESULTS During the study period, 9782 leads were implanted, including 8512 Tendril leads, 731 Medtronic 4076 CapSureFix Novus leads, and 539 FINELINE II leads. A total of 540 leads (5.5%) malfunctioned during a mean follow-up of 3.6 6 2.9 years. Lead malfunction manifested predominantly as noise and/or low impedance (95%). Lead malfunction rates were significantly higher at 5 years for Tendril vs non-Tendril leads (7.0% vs 2.1%; P <.001). The highest rate of failure at 5 years was seen in the Tendril 1888 TC leads (9.9%), followed by Tendril 1688 (5.7%) and Tendril 2088 (5.2%) leads. In contrast, malfunction rates were significantly lower for the Medtronic 4076 (2.6%) and FINELINE II (1.7%) leads. During follow-up to 10 years, the incidence of lead malfunction for Optim-insulated Tendril leads (models 1888 TC and 2088 TC) was significantly higher than that for the non-Optim- insulated Tendril 1688 TC lead (24.5% vs 7.1%) (P = .008).CONCLUSION Tendril leads appear to have a higher rate of malfunction than do comparator leads. Optim insulation may partly explain the higher failure rate.