Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
7058255
Reference Type
Journal Article
Title
Diagnostic accuracy of a rapid E1-antigen test for chikungunya virus infection in a reference setting
Author(s)
Huits, R; Nakayama, EE; Shioda, T; Van Esbroeck, M; Okabayashi, T; Cnops, L; Barbe, B; Van Den Berg, R; Bartholomeeusen, K; Arien, KK; Jacobs, J; Bottieau, E; ,
Year
2018
Is Peer Reviewed?
Yes
Journal
Clinical Microbiology and Infection
ISSN:
1198-743X
EISSN:
1469-0691
Publisher
ELSEVIER SCI LTD
Location
OXFORD
Page Numbers
78-81
PMID
28606643
DOI
10.1016/j.cmi.2017.06.004
Web of Science Id
WOS:000418612600016
Abstract
Objectives: Rapid diagnostic tests targeting virus-specific antigen could significantly enhance the diagnostic capacity for chikungunya virus infections. We evaluated the accuracy of an immunochromatographic antigen test for diagnosis of chikungunya in a reference laboratory for arboviruses.Methods: An immunochromatographic rapid test that uses mouse monoclonal antibodies as a tracer against the E1-envelope protein of chikungunya (ARKRAY, Inc. Kyoto, Japan) was evaluated. Sensitivity was tested in sera from travellers with RT-PCR confirmed chikungunya virus infection (Eastern/Central/Southern African (ECSA) genotype) (n = 9) and from patients diagnosed during the 2014-2015 chikungunya outbreak on Aruba (Asian genotype, n = 30). Samples from patients with other febrile and nonfebrile illnesses (n = 26), sera spiked with Flavivirus and Alphavirus reference strains (n = 13, including non-spiked serum), and samples containing other selected pathogens (n = 20) were used to test specificity of the E1-antigen test.Results: Sensitivity of the E1-antigen test was 8/9 (88.9%, 95% CI 56.5-98.0) for the ECSA genotype, but only 10/30 (33.3%, 95% CI 19.2-51.2) for the Asian genotype. Overall diagnostic specificity was 49/59 (83.1%, 95% CI 71.5-90.5).Conclusions: The E1-antigen test we evaluated had fair diagnostic sensitivity for ECSA genotype chikungunya, but low sensitivity for Asian genotype, and poor overall specificity. Antibodies that react across genotypes will be required for further development of a rapid test for chikungunya. Performance of new tests should be evaluated against different chikungunya genotypes. (C) 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity