Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
7342209
Reference Type
Journal Article
Title
Corrosion of reinforcing steel evaluated by means of concrete resistivity measurements
Author(s)
Morris, W; Vico, A; Vazquez, M; De Sanchez, SR
Year
2002
Is Peer Reviewed?
Yes
Journal
Corrosion Science
ISSN:
0010-938X
EISSN:
1879-0496
Volume
44
Issue
1
Page Numbers
81-99
DOI
10.1016/s0010-938x(01)00033-6
Web of Science Id
WOS:000172339500007
URL
http://
://WOS:000172339500007
Exit
Abstract
The corrosion behaviour of reinforcing steel bars (rebars) in four different concrete mix designs commonly used at coastal cities in Argentina is studied. The investigation has two basic objectives: (1) to evaluate the influence of certain local variables that affect the rebar corrosion process, among which the common practice of using sea sand as a fine aggregate, exposure conditions and typical mix designs are the most important, and (2) to establish a rebar corrosion evaluation criterion based on measurements of concrete electrical resistivity. Two exposure conditions were investigated: seashore environment and partially immersed in a saline solution. Two water to cements and various chloride ions additions were selected for the study. Electrochemical parameters characteristic of the corrosion process were evaluated together with mechanical, chemical and physical properties of the concrete mixes. Rebars in contact with a good quality concrete (f(c) approximate to 30 MPa) exposed for 1000 days to the seashore environment remained in the passive state, even when its surface chloride concentration reached 0.75% with respect to cement content. This behaviour was even better than that observed on a standard-quality uncontaminated concrete (f(c) approximate to 20 MPa). When immersed in a saline solution, all rebar segments presented an active behaviour (E-corr < -0.35 V vs. copper sulphate electrode and i(corr) > 0.2 muA cm(-2)). although the CR depended primarily on the concrete quality and the initial chloride concentration. The electrical resistivity of concrete has proven to be an effective parameter to evaluate the risk of reinforcing steel corrosion independently of mix design and exposure condition. Rebars are likely to achieve an active state of corrosion when rho is lower than 10 k Omega cm, and likely to present a passive behaviour when concrete resistivity is higher than 30 k Omega cm. (C) 2001 Elsevier Science Ltd. All rights reserved.