Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
8350918
Reference Type
Journal Article
Title
é«èç©é»ç»ç¸è¯CTå¾ååç´ çº§è£çº¹è¯å«æ¹æ³ç ç©¶
Author(s)
Zhang, T; Zong, HH; Chen, H; Dai, B; Liu, BD; Luo, JZ
Year
2020
Is Peer Reviewed?
1
Journal
Hanneng Cailiao / Chinese Journal of Energetic Materials
ISSN:
1006-9941
Publisher
Institute of Chemical Materials, China Academy of Engineering Physics
Volume
28
Issue
5
Page Numbers
442-448
Language
Chinese
DOI
10.11943/CJEM2019032
Abstract
In order to effectively improve the accuracy of crack identification and crack characterization method, this research has focused on the problem of dark fields, low contrast and high noise in the computed tomography (CT) images of HMX-based polymer bonded explosives (PBXs). We propose a new algorithm. By using the density and local-orientation of cracks, the algorithm first preprocesses the source image by integrating the non-local mean algorithm, the Laplacian sharpening algorithm and the Gamma sharpening algorithm. Then, it adopts the statistical method to extract directly cracks' feature-points, which is used to derive the positions, orientations and thicknesses of cracks via the local orientation among these points measured by the Mahalanobis distance. Finally, it copies the gray values of pixels from the source image, to realize fine recognitions of continuous cracks from CT images of HMX-based PBXs. Comparative experiments were conducted, on CT images of thermal-force compound loading cracks from three PBXs, by this proposed Mahalanobis distance based crack extraction(MDCE) algorithm, Canny edge detection algorithm and phase consistency method, respectively. Results show that this proposed MDCE algorithm can extract various cracks clearly and accurately cracks from CT images with low quality, which indicates the high effectiveness of this method and enhances the ability of crack recognition and characterization. © 2020, Editorial Board of Chinese Journal of Energetic Materials. All right reserved.
Keywords
Carney algorithm; Crack recognition; CT image; Mahalanobis distance; Polymer bonded explosive (PBX)
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity