Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
8383013
Reference Type
Journal Article
Title
Simultaneous determination of the main components in carboprost tromethamine injection by HPLC-UV-CAD
Author(s)
Zhou, J; Jiang, H; Yao, J; Ren, LJ; Zuo, LM; Jiang, W; Shan, GZ
Year
2015
Publisher
Chinese Journal of New Drugs Co. Ltd.
Volume
24
Issue
1
Page Numbers
22-26 and 51
Language
Chinese
Abstract
Objective: To establish an HPLC-UV-CAD method for the simultaneous determination of carboprost, tromethamine and benzyl alcohol in carboprost tromethamine injection. Methods: Carboprost, tromethamine and benzyl alcohol were separated on a CAPCELL PAK CR 1â¶4 column (150 mmÃ4.6 mm,5 μm). The mobile phase was composed of ultrapure water, 0.1 mol·L-1 ammonium acetate buffer (pH 6.2) and methanol with gradient elution mode at a flow about 1.0 mL·min-1; the injection volume was 10 μL and column temperature was 40 â. CAD was used to detect carboprost and tromethamine, in which nebulization temperature was 35 â and collection frequency was 30 Hz. UV was used to detect benzyl alcohol, in which detection wavelength was set at 258 nm and collection frequency was 5 Hz. Results: The linear range of carboprost was 9.38~56.2 μg·mL-1(r=0.997 1, n=6); the lowest limit of detection was 0.3 μg·mL-1; LOQ was 0.6 μg·mL-1; average recovery was 104.7%. The linear range of tromethamine was 5.19~23.3 μg·mL-1(r=0.999 2, n=6); the lowest limit of detection was 1 μg·mL-1; LOQ was 2.5 μg·mL-1; average recovery was 95.5%. The linear range of benzyl alcohol was 0.297~1.78 mg·mL-1(r=1, n=6), the lowest limit of detection was 5.0 μg·mL-1; LOQ was 10.0 μg·mL-1; average recovery was 100.1%. The actual measurement results of the sample were consistent with the standard method currently used. Conclusion: The HPLC method established does not require derivative operations, and is cheap, sensitive, simple, accurate, reproducible and accurate. This method can simultaneously detect carboprost, tromethamine and benzyl alcohol in carboprost tromethamine injection. ©, 2014, Chinese Journal of New Drugs Co. Ltd. All right reserved.
Keywords
Carboprost tromethamine injection; Charged aerosol detection(CAD); Determination; HPLC; Mixed-mode column
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity