Title
Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
Author(s)
Hasegawa, C; Kumazawa, T; Uchigasaki, S; Lee, XP; Sato, K; Terada, M; Kurosaki, K
Year
2011
Is Peer Reviewed?
Yes
Journal
Analytical and Bioanalytical Chemistry
ISSN:
1618-2642
EISSN:
1618-2650
Volume
401
Issue
7
Page Numbers
2215-2223
Language
English
PMID
21874269
DOI
10.1007/s00216-011-5324-5
Abstract
Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.
Keywords
Dextromethorphan; Solid-phase extraction; Pipette tip; Gas chromatography; Mass spectrometry