Tags
HERO ID
1051553
Reference Type
Journal Article
Title
Determination of bisphenol A in milk by solid phase extraction and liquid chromatography-mass spectrometry
Author(s)
Maragou, NC; Lampi, EN; Thomaidis, NS; Koupparis, MA
Year
2006
Is Peer Reviewed?
Yes
Journal
Journal of Chromatography A
ISSN:
0021-9673
EISSN:
1873-3778
Volume
1129
Issue
2
Page Numbers
165-173
Language
English
PMID
16879831
DOI
10.1016/j.chroma.2006.06.103
Web of Science Id
WOS:000240879200003
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-33748558115&doi=10.1016%2fj.chroma.2006.06.103&partnerID=40&md5=eb0d8ce33a45e9343306654385edf484
Exit
Abstract
A simple and reliable analytical method based on solid phase extraction (SPE) and liquid chromatography coupled with electrospray ionization mass spectrometry was developed for the determination of bisphenol A (BPA) in milk. The effects of the experimental parameters of the LC-ESI-MS system (mobile phase and additives, flow rate, temperature of the ionization source, cone voltage and capillary potential) on the obtained signal were assessed and the parameters were optimized to provide maximum sensitivity and detectability. In addition, the performance of three commercial SPE sorbents (C18, PS-DVB and hydroxylated PS-DVB) was evaluated using spiked water and milk, diluted with a mixture of water-methanol (8:1). By using C18 cartridges and BPA-d(16) as internal standard, the mean relative recoveries at three fortification levels ranged between 97 and 104% and the corresponding inter-day precision (RSD%) was below 6% for 50 and 500 ng/g and below 20% for 5 ng/g fortification levels. It is shown that the ion suppression during ESI, the losses from the sample preparation procedure and the inter-day instability of LC-ESI-MS were overcome by the use of the deuterated internal standard. The concentration of BPA found in commercial canned milk samples ranged from <1.7 to 15.2 ng/g.
Keywords
BPA; food analysis; LC-ESI-MS; isotope labeled internal standard; SPE