Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
2851081
Reference Type
Journal Article
Title
Fixation of intertrochanteric femur fractures using Proximal Femoral Nail Antirotation (PFNA) in the lateral decubitus position without a traction table
Author(s)
Turgut, A; Kalenderer, Ö; Günaydın, B; Önvural, B; Karapınar, L; Ağuş, H
Year
2014
Is Peer Reviewed?
Yes
Journal
Acta Orthopaedica et Traumatologica Turcica
ISSN:
1017-995X
Volume
48
Issue
5
Page Numbers
513-520
Language
English
PMID
25429576
DOI
10.3944/AOTT.2014.14.0098
Web of Science Id
WOS:000345260900009
Abstract
OBJECTIVE:
The aim of this study was to evaluate whether intertrochanteric femur fractures can be reduced and nailed properly in the lateral decubitus position using Proximal Femoral Nail Antirotation (PFNA) as a fixation device without the use of a traction table.
METHODS:
The study included 207 patients (81 male and 126 female; mean age: 75 years, range: 22 to 95 years). According to the Evans classification, there were 7 Type 1, 40 Type 2, 33 Type 3, 38 Type 4, 61 Type 5 and 28 reverse oblique fractures. Radiographs were used to measure the tip-apex distance (TAD), the quadrant of the helical blade according to Cleveland and Bosworth, Ikuta's reduction subgroup, collodiaphyseal angle and reduction gaps postoperatively.
RESULTS:
Mean follow-up time was 20.4 (range: 6 to 38) months. According to Ikuta's classification, 176 (85%) reduced fractures were of subtype N, 15 (7.2%) subtype P and 16 (7.7%) subtype A. Good or acceptable reduction according to the Herman criteria was obtained in 99% of fractures. Mean TAD was 29.2 millimeters. Mean operation time was 57.2 minutes. Optimal blade position (center-center or inferior-center) was achieved in 53.5% of patients and was in the superior-posterior quadrants in only 2.4% of patients. Cut-out complication occurred in 9 patients (4.3%).
CONCLUSION:
While the nailing of intertrochanteric fractures in a lateral decubitus position does not provide ideal quadrant placement and TAD, results are encouraging probably due to the excellent stability that is provided by PFNA.
Tags
PFAS
•
Additional PFAS (formerly XAgency)
•
PFAS 150
Literature Search August 2019
PubMed
Not prioritized for screening
Perfluorononanoic acid
•
PFNA
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity