Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
3227138
Reference Type
Journal Article
Title
A new cataluminescence-based gas sensor for simultaneously discriminating benzene and ammonia
Author(s)
Fan, H; Peng, Z; Yang, H; Zhou, K
Year
2016
Is Peer Reviewed?
1
Journal
Analytical Methods
ISSN:
1759-9660
EISSN:
1759-9679
Volume
8
Issue
6
Page Numbers
1257-1264
Language
English
DOI
10.1039/c5ay03193a
Web of Science Id
WOS:000370332700007
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84957677899&doi=10.1039%2fc5ay03193a&partnerID=40&md5=157677c0f7a4f89ca1b0dc4a58361ae7
Exit
Abstract
An efficient method based on cross-cataluminescence (CTL) on nano-Bi4SnV2O13 was proposed for simultaneously discriminating benzene and ammonia in air. The experimental conditions meeting the algebraic sum rule of the CTL intensities of benzene and ammonia were sought. They are two analysis wavelengths of 475 nm and 550 nm, the surface temperature of sensing materials of 150 degrees C and the flow rate of air carrier of 250 ml min(-1). The limits of detection of this method were 0.12 mg m(-3) for benzene and 0.21 mg m(-3) for ammonia. The linear ranges of CTL intensity versus analyte concentration were 0.2-66.3 mg m(-3) for benzene and 0.4-81.7 mg m(-3) for ammonia. The recoveries of 10 tested standard samples by this method were 97.1%-102.2% for benzene and 97.6%-103.1% for ammonia. Common coexistence matters, such as toluene, ethylbenzene, methylamine, ethylamine, formaldehyde, acetaldehyde, methanol, ethanol, sulfur dioxide and carbon dioxide, did not disturb the determination. The relative deviation (RD) of CTL intensities was less than 2% for continuous 120 h detection for a gaseous mixture containing benzene and ammonia, which demonstrated the longevity and steady performance of nano-Bi4SnV2O13 in the presence of benzene and ammonia.
Keywords
article; acetaldehyde; ammonia; analytical methods; benzene; carbon dioxide; detection limit; ethanol; ethylbenzene; formaldehyde; longevity; methanol; methylamine; sensors (equipment); sulfur dioxide; surface temperature; toluene; wavelengths
Tags
•
Phthalates – Targeted Search for Epidemiological Studies
Excluded
Source - August 2017 Update (Private)
WOS - Forward Search Results
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity