Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
6357960
Reference Type
Journal Article
Title
Determination of Femtogram-Level Plutonium Isotopes in Environmental and Forensic Samples with High-Level Uranium Using Chemical Separation and ICP-MS/MS Measurement
Author(s)
Hou, X; Zhang, W; Wang, Y
Year
2019
Is Peer Reviewed?
Yes
Journal
Analytical Chemistry
ISSN:
0003-2700
EISSN:
1520-6882
Volume
91
Issue
18
Page Numbers
11553-11561
Language
English
PMID
31418263
DOI
10.1021/acs.analchem.9b01347
Web of Science Id
WOS:000487156900012
Abstract
ICP-MS is becoming a competitive technique for measurement of plutonium isotopes. Besides the abundance sensitivity (tailing of 238U to m/z = 239 and 240), isobaric and polyatomic ions interferences (e.g., 238U1H+) are the most critical challenges for determination of low-level plutonium in high uranium samples. This work presents a new method to solve this problem using ICP-MS with two tandem quadrupole separators and a dynamic collision/reaction cell combined with chemical separation. The interference of uranium hydrides (238U1H+ and 238U1H2+) was effectively eliminated using CO2 as reaction gas by converting hydrides to oxides of uranium ions (UO+/UO2+) but still keeping the intensity of the Pu+ signal. The tailing interference of 238U+ (abundance sensitivity) was intensively eliminated by significantly suppressing the 238U+ signal using CO2 as reaction gas and using two tandem quadrupole mass separators in the ICP-MS/MS. With these approaches the overall interference of uranium was reduced to <1 × 10-8, which is 3 orders of magnitude better than the conventional ICP-MS. Combined with chemical separation with a decontamination factor of 105 for uranium, an overall factor of 1012 for elimination of uranium interference was achieved. The developed method was demonstrated to enable accurate determination of <10-15 g/g level plutonium isotopes in environmental samples even in a uranium debris sample with a U/Pu atomic ratio of up to 1012. The developed method was validated by analysis of a spiked solution and certified reference materials of soil.
Tags
IRIS
•
Uranium
Uranium Literature Search Update 4/2020
WOS
•
Uranium Toxicological Review
Date limited literature search 2011-2021
New to this search
WOS
Exposure Criteria by Research Topic
Occupational exposure - validated measures
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity