Title
An automated method for the simultaneous measurement of azole antifungal drugs in human plasma or serum using turbulent flow liquid chromatography-tandem mass spectrometry
Author(s)
Couchman, L; Buckner, SL; Morgan, PE; Ceesay, MM; Pagliuca, A; Flanagan, RJ
Year
2012
Is Peer Reviewed?
Yes
Journal
Analytical and Bioanalytical Chemistry
ISSN:
1618-2642
EISSN:
1618-2650
Volume
404
Issue
2
Page Numbers
513-523
Language
English
PMID
22695504
DOI
10.1007/s00216-012-6176-3
Web of Science Id
WOS:000306330000024
Abstract
Azole antifungal drugs are important in the prophylaxis and treatment of invasive aspergillosis. Therapeutic drug monitoring may be indicated to (1) monitor adherence, (2) guide dosage and (3) minimise the risk of drug-drug interactions and dose-related toxicity. TurboFlow(TM) technology offers online, automated sample preparation. An Aria Transcend(TM) TLX-II coupled with a TSQ Vantage(TM) MS was used. Centrifuged samples (25 μL) were mixed with internal standard solution (975 μL) and 30 μL injected directly onto a C18-P-XL TurboFlow column. Analytes were focussed onto a Phenomenex Gemini Phenyl analytical column and eluted using a methanol/water gradient (flow-rate, 0.8 mL/min). Analytes were monitored in selected reaction monitoring mode (two transitions per analyte, positive mode APCI). Calibration ranges were as follows: itraconazole, hydroxyitraconazole, and posaconazole 0.05-5.0 mg/L; voriconazole and fluconazole 0.1-10 mg/L. Total analysis time was 12 min. TurboFlow column recovery was >77% for all analytes. Calibration was linear (R (2) > 0.99) for all analytes. Inter- and intra-assay imprecision (% RSD) was <8% and accuracy (nominal internal quality control values) 90-105% for all analytes. The limit of detection was 0.01 mg/L for all analytes. No matrix effects were observed. This method is simple, robust and suitable for measuring these compounds at concentrations attained during therapy.
Keywords
TurboFlow MS/MS; Azole antifungals; Itraconazole; Posaconazole; Voriconazole; Automated sample preparation