Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
2079002
Reference Type
Journal Article
Title
Relation of spirometric function to radiographic interstitial fibrosis in two large workforces exposed to asbestos: An evaluation of the ILO profusion score
Author(s)
Miller, A; Lilis, R; Godbold, J; Wu, X
Year
1996
Is Peer Reviewed?
1
Journal
Occupational and Environmental Medicine
ISSN:
1351-0711
EISSN:
1470-7926
Report Number
BIOSIS/97/03342
Volume
53
Issue
12
Page Numbers
808-812
Language
English
PMID
8994399
DOI
10.1136/oem.53.12.808
Web of Science Id
WOS:A1996VX24800003
Abstract
OBJECTIVES:
To analyse quantitatively the relations of spirometric lung function (forced vital capacity (FVC)) to radiographic interstitial pulmonary fibrosis (assessed by the International Labour Organisation (ILO) profusion score of small irregular opacities) in two large workforces exposed to different intensities of asbestos. These analyses consider the question whether a similar profusion score n differently exposed workers is associated with a similar effect on lung function.
METHODS:
Surveys of two workforces, insulators (n = 2611) and sheet metal workers (n = 1245), by the same investigators allowed comparison of the effects of the two levels of exposure to asbestos. The two groups were of similar age and had similar percentages of non-smokers and smokers. All radiographs were read by the same expert reader.
RESULTS:
Consistent with their less continuous and less intense exposure to asbestos, metal workers had: (a) far less frequent radiographic asbestosis (profusion score > or = 1/0, 17.5% v 59.6% for insulators): (b) less severe radiographic asbestosis (only 1.1% had scores > or = 2/1 v 13.3% of insulators); (c) a similar slope to that seen in insulators for the relation between FVC and profusion score when pleural thickening was absent; (d) less frequent pleural fibrosis (36% v 75%); and (e) less frequent restrictive impairment (23% v 33%). In both insulators and metal workers, lung function was below normal even when lung fields were normal, FVG fell with increasing profusion, it was lower in smokers and in those with pleural thickening at comparable profusion scores, and these was no difference in FVC between scores 0/1 and 1/0.
CONCLUSION:
The decrease in FVC with increasing profusion score in both workforces as well as the similar slopes for the relation between FVG and profusion score and the similar FVG at similar scores in the absence of pleural thickening confirm the ILO profusion score as an acceptable assessment of pulmonary fibrosis.
Keywords
spirometry; fibrosis; asbestos; International Labour Organisation classification
Tags
IRIS
•
Libby Amphibole Asbestos (Draft, 2011)
Pulmonary Function Search, Sept 2013
Database Search
Full Text Screening
Not primary source but additional resource
OPPT REs
•
OPPT_Asbestos, Part I: Chrysotile_A. Summary
Suggested Literature: Public Comments
•
OPPT_Asbestos, Part I: Chrysotile_C. Engineering
Total – title/abstract screening
On topic
Peer review
Primary source
•
OPPT_Asbestos, Part I: Chrysotile_D. Exposure
Total – title/abstract screening
Off topic
•
OPPT_Asbestos, Part I: Chrysotile_E. Fate
Total – title/abstract screening
Off topic
•
OPPT_Asbestos, Part I: Chrysotile_F. Human Health
Total – title/abstract screening
On topic
Peer review
Primary source
On topic - additional tags for titles/abstracts
Human hazard ID
Asbestosis
•
OPPT_Asbestos, Part I: Chrysotile_Supplemental Search
LitSearch: Sept 2020 (Undated)
ProQuest
PubMed
Toxline
WoS
Legacy Uses
Health Outcomes
Exposure
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity