Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
2139991
Reference Type
Book/Book Chapter
Title
Zero-energy removal of ozone in residences
Author(s)
Gall, E; Siegel, JA; Corsi, R
Year
2011
Publisher
American Society of Heating, Refrigerating and Air-Conditioning Engineers
Location
Atlanta, GA
Book Title
ASHRAE transactions 2011: Papers presented at the 2011 Winter Conference in Las Vegas, Nevada
Page Numbers
411-418
Language
English
Web of Science Id
WOS:000295933900050
Abstract
Ozone is present indoors largely as a result of transport from outdoors. Conventional strategies to remove ozone require energy and thus are not appropriate for zero-energy buildings. We explore the use of passive reactive materials (PRMs), indoor surfaces that remove ozone with no additional energy input and without producing byproducts, to reduce indoor ozone concentrations. This work presents the results of a Monte Carlo simulation to assess the ozone removal effectiveness of active and passive methods of indoor ozone removal. We compare two different PRMs to stand-alone activated carbon filtration and HVAC filtration. Housing stock data for approximately 100 homes in Houston, TX are taken from the literature to calculate energy and material requirements to achieve 50% and 80% indoor ozone removal effectiveness in these homes. Model results indicate that to achieve 50% ozone removal in half of the homes requires approximately 30 kWh and 5 kWh per home each day for stand-alone filtration and HVAC filtration, respectively. To achieve this same level of indoor ozone reduction with PRMs requires 75 m(2) (807 ft(2)) for activated carbon cloth and 200 m(2) (2153 ft(2)) of unpainted gypsum wallboard. These results indicate that PRM use represents a viable option for zero-energy control of indoor ozone.
Editor(s)
Ramanathan, G
Series
ASHRAE Transactions, vol. 117, pt. 1
ISBN
9781223009322
Conference Name
Winter Conference of the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE)
Conference Location
Las Vegas, NV
Conference Dates
2011
Tags
NAAQS
•
ISA-NOx (2016)
Considered
Health Effects
•
ISA-Ozone (2020 Final Project Page)
Literature Search Results
Literature Search - Included
Keyword Search
Topic Classified Exposure
Title-Abstract Screening (SWIFT-AS) - Included
Title-Abstract Screening (SWIFT-AS) - Included
Full-Text Screening Excluded
Full-Text Screening Excluded
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity