Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide 
Lin, C; Gillespie, J; Schuder, MD; Duberstein, W; Beverland, IJ; Heal, MR 
2015 
Atmospheric Environment
ISSN: 1352-2310
EISSN: 1873-2844 
100 
111-116 
English 
Low-power, and relatively low-cost, gas sensors have potential to improve understanding of intra-urban air pollution variation by enabling data capture over wider networks than is possible with 'traditional' reference analysers. We evaluated an Aeroqual Ltd. Series 500 semiconducting metal oxide O-3 and an electrochemical NO2 sensor against UK national network reference analysers for more than 2 months at an urban background site in central Edinburgh. Hourly-average Aeroqual O-3 sensor observations were highly correlated (R-2 = 0.91) and of similar magnitude to observations from the UV-absorption reference O-3 analyser. The Aeroqual NO2 sensor observations correlated poorly with the reference chemiluminescence NO2 analyser (R-2 = 0.02), but the deviations between Aeroqual and reference analyser values ([NO2](Aeraq) - [NO2](ref)) were highly significantly correlated with concurrent Aeroqual O-3 sensor observations [O3](Aeroq). This permitted effective linear calibration of the [O3](Aeroq) data, evaluated using 'hold out' subsets of the data (R-2 >= 0.85). These field observations under temperate environmental conditions suggest that the Aeroqual Series 500 NO2 and O-3 monitors have good potential to be useful ambient air monitoring instruments in urban environments provided that the O-3 and NO2 gas sensors are calibrated against reference analysers and deployed in parallel. (C) 2014 The Authors. Published by Elsevier Ltd. 
Semiconductor gas sensor; Electrochemical gas sensor; NO2; O-3; Air pollution exposure 
• ISA-Ozone (2020 Final Project Page)
     Literature Search Results
     Literature Search - Included
          Keyword Search
               Topic Classified Exposure
     Title-Abstract Screening (SWIFT-AS) - Included
          Title-Abstract Screening (SWIFT-AS) - Included
     Full-Text Screening Excluded
          Full-Text Screening Excluded
• ISA-PM (2019)
• LitSearch-NOx (2024)
     Forward Citation Search
          Exposure
               Results
                    Confounding
                         WoS
                    PIA
                         WoS
     Keyword Search
          Exposure
               Confounding
                    WoS
               PIA
                    WoS
               Error Sources
                    WoS
     TIAB Screening
          Atmospheric
               Round 1
                    Exclude
• WFLC - CAIF Report
     Chapter 4