Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
3134743
Reference Type
Journal Article
Title
Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion
Author(s)
Sun, Z; Xie, M; Xiang, F; Song, Y; Yu, C; Zhang, Y; Ramdhany, S; Wang, J
Year
2015
Is Peer Reviewed?
1
Journal
PLoS ONE
EISSN:
1932-6203
Volume
10
Issue
9
Page Numbers
e0138523
Language
English
PMID
26382244
DOI
10.1371/journal.pone.0138523
Abstract
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07±9.01 kPa vs 22.0±5.10 kPa; Emax, 94.07±6.53 kPa vs 27.87±5.78 kPa; Emin, 60.73±7.84 kPa vs 18.90±4.39 kPa; SD, 7.67±0.60 kPa vs 2.30±0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23±0.30 kPa vs 3.97±0.95 kPa; SD, 1.5±0.26 kPa vs 0.67±0.35 kPa,[P<0.05]) and Emin values was lower than those of normal testicles (0.93±0.51 kPa vs 1.6±0.36 kPa; [P<0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
Tags
•
PCBs
Litsearches
PubMed
Restored references_April 2024
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity