Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
2158803
Reference Type
Journal Article
Title
Palladium-facilitated electrolytic dechlorination of 2-chlorobiphenyl using a granular-graphite electrode
Author(s)
Fang, Y; Al-Abed, SR
Year
2007
Is Peer Reviewed?
Yes
Journal
Chemosphere
ISSN:
0045-6535
EISSN:
1879-1298
Volume
66
Issue
2
Page Numbers
226-233
Language
English
PMID
16837025
DOI
10.1016/j.chemosphere.2006.05.057
Web of Science Id
WOS:000243863000005
Abstract
Palladium-assisted electrocatalytic dechlorination of 2-chlorobiphenyl (2-Cl BP) in aqueous solutions was conducted in a membrane-separated electrochemical reactor with granular-graphite packed electrodes. The dechlorination took place at a granular-graphite cathode while Pd was electro-deposited from the K2PdCl6 in the solution and at a Pd-deposited granular-graphite electrode. Using the Pd-deposited graphite cathode in the membrane reactor for a sequence of experiments, each was conducted under a lower current than in the previous one, and the rate of dechlorination became slower in each consecutive experiment. At the end of this sequence, a duplicate experiment showed a loss of activity of the Pd-deposited granular-graphite cathode. In the experiments of dechlorination while Pd was deposited at the granular-graphite electrode, the rate of dechlorination increased with increases of the initial K2PdCl6 concentration and of the applied cathode potential. In each experiment, the dechlorination of 2-Cl BP was relatively fast at the beginning, as demonstrated in an experiment in which 66.4% of 2-Cl BP was dechlorinated within 4h, but the rate of dechlorination decreased over the time. This decrease can be described with two stages of exponential decrease. The values of the rate constant in the first stage varies with the applied potential and the initial K2PdCl6 concentration, but the values of the rate constant in the second stage do not show any dependence on the potential and the K2PdCl6 concentration. The current efficiency of dechlorination was improved by applying part-time current to the electrodes.
Keywords
PCBs; electrocatalytic dechlorination; granular-graphite electrode; palladium-facilitated electrolytic dechlorination
Tags
IRIS
•
PCBs
Litsearches
Remaining
LitSearch August 2015
Pubmed
Toxline
WoS
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity