Citation
Tags
HERO ID
3491115
Reference Type
Journal Article
Title
Preparation and application of a coated-fiber needle extraction device
Author(s)
Lou, D; Chen, H; Wang, X; Lian, L; Zhu, B; Yang, Q; Guo, T; Li, Q; Wang, R; Guo, X
Year
2016
Is Peer Reviewed?
Yes
Journal
Journal of Separation Science
ISSN:
1615-9306
EISSN:
1615-9314
Volume
39
Issue
19
Page Numbers
3769-3774
Language
English
PMID
27501511
DOI
10.1002/jssc.201600410
Web of Science Id
WOS:000389044300014
URL
https://www.proquest.com/docview/2020896633?accountid=171501&bdid=64576&_bd=Eh%2FoBQTzlnuB1yMu2Z9M%2Fug%2BLGY%3D
Exit
Abstract
In this study, a needle-trap device with fibers coated with a molecularly imprinted polymer was developed for separation. A number of heat-resistant Zylon filaments were longitudinally packed into a glass capillary, followed by coating with a molecularly imprinted polymer. Then, the molecularly imprinted polymer coating was copolymerized and anchored onto the surface of the fibers. The bundle of synthetic fibers coated with the molecularly imprinted polymer was packed into a 21G stainless-steel needle and served as an extraction medium. The coated-fiber needle extraction device was used to extract volatile organic compounds from paints and gasoline effectively. Subsequently, the extracted volatile organic compounds were analyzed by gas chromatography. Calibration curves of gaseous benzene, toluene, ethylbenzene, and o-xylene in the concentration range of 1-250 μg/L were obtained to evaluate the method, acceptable linearity was attended with correlation coefficients above 0.998. The limit of detection of benzene, toluene, ethylbenzene, and o-xylene was 11-20 ng/L using the coated-fiber needle-trap device. The relative standard deviation of needle-to-needle repeatability was less than 8% with an extraction time of 20 min. The loss rates after storage for 3 and 7 days at room temperature were less than 30%.
Tags
•
Ethylbenzene
Database searches
PubMed
Update search - Jan 2017 (private)
Database searches - Jan 2017 (private)
New - Jan 2017 (private)
LitSearch Update 2019
PubMed
New Litsearch 4/2019
PubMed
Pre-2020 Screening HERO tags
Data set for title/abstract screening
Excluded – PECO criteria not met
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity