Health & Environmental Research Online (HERO)


Print Feedback Export to File
1060834 
Journal Article 
Residential air exchange rates in three major US metropolitan areas: Results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999–2001 
Yamamoto, N; Shendell, D; Winer, A; Zhang, J 
2010 
Yes 
Indoor Air
ISSN: 0905-6947
EISSN: 1600-0668 
20 
85-90 
English 
We report approximately 500 indoor-outdoor air exchange rate (AER) calculations based on measurements conducted in residences in three US metropolitan areas in 1999-2001: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Overall, a median AER across these urban areas and seasons was 0.71 air changes per hour (ACH, or per hour; n = 509) while median AERs measured in California (n = 182), New Jersey (n = 163), and Texas (n = 164) were 0.87, 0.88, and 0.47 ACH, respectively. In Texas, the measured AERs were lower in the summer cooling season (median = 0.37 ACH) than in the winter heating season (median = 0.63 ACH), likely because of the reported use of room air conditioners as Houston is typically hot and humid during the summer. The measured AERs in California were higher in summer (median = 1.13 ACH) than in winter (median = 0.61 ACH). Because the summer cooling season in Los Angeles County is less humid than in New Jersey or Texas, natural ventilation through open windows and screened doors likely increased measured AER in California study homes. In New Jersey, AER were similar across heating and cooling seasons, although the median AER was relatively lower during the spring.

PRACTICAL IMPLICATIONS: Adequate ventilation or air exchange rate (AER) for an indoor environment is important for human health and comfort, and relevant to building design and energy conservation and efficiency considerations. However, residential AER data, especially measured by more accurate non-toxic tracer gas methodologies, are at present quite limited worldwide, and are insufficient to represent the variations across regions and seasons within and between homes, including apartments and condominiums in more densely populated urban areas. The present paper presents quantitative and qualitative data to characterize residential AERs in three US urban areas with different climate attributes. 
Air exchange rate; Perfluoro-methyl-cyclohexane; Air changes per hour; Ventilation rates; Perfluorocarbon tracer gas; Urban residences 
NAAQS
• ISA-PM (2019)
     1st Draft
          Chapter 3
     Final ISA
          Chapter 3
• ISA-SOx
     Cited Second ERD Dec2016
     Cited in Final ISA Dec2017
• Exposure Factors Handbook (Post 2011)
     Chapter 19
• WFLC - CAIF Report
     Chapter 6