Jump to main content
US EPA
United States Environmental Protection Agency
Search
Search
Main menu
Environmental Topics
Laws & Regulations
About EPA
Health & Environmental Research Online (HERO)
Contact Us
Print
Feedback
Export to File
Search:
This record has one attached file:
Add More Files
Attach File(s):
Display Name for File*:
Save
Citation
Tags
HERO ID
3859218
Reference Type
Journal Article
Title
Rapid and sensitive determination of sertraline in human plasma using gas chromatography-mass spectrometry
Author(s)
Kim, KM; Jung, BH; Choi, MH; Woo, JS; Paeng, KJ; Chung, BC
Year
2002
Is Peer Reviewed?
Yes
Journal
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
ISSN:
1570-0232
EISSN:
1873-376X
Volume
769
Issue
2
Page Numbers
333-339
Language
English
PMID
11996499
DOI
10.1016/S1570-0232(02)00027-2
Web of Science Id
WOS:000174613800014
Abstract
A method for the determination of sertraline in human plasma using gas chromatography-mass spectrometry (GC-MS), with the selected ion-monitoring (SIM) mode, was described. The following was used in this study: (1) single liquid-liquid extraction at alkaline pH after deproteinization of plasma protein and (2) perfluoroacylation with HFBA, which has higher sensitivity (about 10-fold) compared with previous reported derivatization. The detection limit for the SIM of sertraline as an N-HFB derivative was 0.1 ng/ml, and its recovery was 80-85%. The linear response was obtained in the range of 0.2-10.0 ng/ml with a correlation coefficient of 0.999. The coefficient of variation (C.V.%) was less than 12.1% in the 1-30 ng/ml, and less than 18.2% at 0.2 ng/ml, and the accuracy was less than 10% at all of the concentration range. These findings indicate that this assay method has adequate precision and accuracy to determine the amount of sertraline in human plasma. After pharmacokinetics was performed with this assay method following oral administration of sertraline hydrochloride in man, moment analysis revealed that pharmacokinetic parameters for sertraline (Cmax, 10.3 ng/ml; Tmax, 8.0 h; T(1/2) 28.6 h) were similar to previously reported results. These results indicate that this simple and sensitive assay method is readily applicable to the pharmacokinetic studies of sertraline.
Keywords
perfluoroacylation; sertraline
Tags
PFAS
•
^Per- and Polyfluoroalkyl Substances (PFAS)
PFBA (375-22-4)
Literature Search
Pubmed
WOS
•
PFBA
Literature Search
Pubmed
WOS
Screening Results
Excluded/Not on Topic
Protocol References
Scopus: April 2021
Home
Learn about HERO
Using HERO
Search HERO
Projects in HERO
Risk Assessment
Transparency & Integrity